Articles and Information

 E-mail

Listed below is a small selection of articles and downloads to help you with your project.

Of course, if you cannot find what you are looking for then please call us on 01242 254 222 and we will be very happy to help you.

 

icon Conservatory Checklist when getting quotes in (11.31 kB)

icon Conservatory Planning Permission Guidelines (13.34 kB)

icon GGF Consumer Code (437.68 kB)

icon Obscured Glass Texture Presenter (2.49 MB)

icon PVCu - The Facts (90 kB)

icon Regent Windows Guarantee 2017 (12.71 kB)

icon Sensations colour chart August 2016 (1.43 MB)

icon Solidor Composite Door Brochure 2016 (7.68 MB)

icon Solidor PVCu panel door (7.05 MB)

icon Terms and Conditions May2015 (23.86 kB)

icon Ventilation Guide (248.51 kB)

icon Visofold 1000 rebated standard threshold (126.17 kB)

icon Aluminium door panels (7.98 MB)

Weights and Measures
Weights and Measures
Useful numbers and addresses

Cheltenham Borough Council

Building Control - 01242 775 160

Planning Department - 01242 264 142

Part N – Glazing Safety: the safety standards my windows need to have

All glass in doors must be toughened, likewise with glass sidepanels:

  • Glass which starts less than 800mm above the finished floor level must be toughened
  • Glass within 300mm either side of a door must be toughened
  • Where large glass panels form part of the structure of a building, there must be visible ‘manifestations’ at a height of 1500mm so that people do not walk in to them (largely commercial applications)
Part L1B - Conservation of fuel + power in existing dwellings

For newbuilds, windows must achieve a ‘U’ value of 2.0 or better. Replacement windows need to achieve a ‘U’ value of 1.6 or better. For ease of understanding, windows are referred to as having a ‘Rating’ of A – G; where ‘A’ is the best rating and ‘G’ is the poorest.

As of October 1st 2010, the minimum window rating was raised from ‘E’ to ‘C’; we at Regent were unconcerned with this since all our windows already had a ‘C’ rating. However, we like a challenge so we did a little experimenting and found that all we needed to do to take our windows from a (very respectable!) ‘C’ rating to an ‘A’ rating was to fill the window unit (sealed unit) with Argon gas. The typically costs between £5-15 per window and will give you the highest window rating possible!

icon Part 1LB - Conservation of Fuel
Part L1A - Conservation of Fuel + Power in New Dwellings

For newbuilds, windows must achieve a ‘U’ value of 2.0 or better. Replacement windows need to achieve a ‘U’ value of 1.6 or better. For ease of understanding, windows are referred to as having a ‘Rating’ of A – G; where ‘A’ is the best rating and ‘G’ is the poorest.

As of October 1st 2010, the minimum window rating was raised from ‘E’ to ‘C’; we at Regent were unconcerned with this since all our windows already had a ‘C’ rating. However, we like a challenge so we did a little experimenting and found that all we needed to do to take our windows from a (very respectable!) ‘C’ rating to an ‘A’ rating was to fill the window unit (sealed unit) with Argon gas. The typically costs between £5-15 per window and will give you the highest window rating possible!

Dowload the L1A document here
Part M - Access to and use of buildings: getting in and out
  • New builds must take into account wheelchair access
  • Anything being changed or replaced in an existing building must be no less satisfactory than that which it is replacing
Dowload the document here
Part F – Ventilation: the change of ‘stale’ indoor air and its replacement with ‘fresh’ outside air

Ventilation is required for:

  • The provision of outside air for breathing
  • The dilution and removal of airborne pollutants, including odours
  • The control of excess humidity
  • To provide air for fuel burning appliances

Ventilation in newbuilds; all windows must have trickle vents.
Ventilation in existing builds; it is advisable (though not mandatory) that replacement windows be fitted with trickle vents. Replacement windows need only have trickle ventilation where the original windows had them

Download the Part F Guidelines
Part B – Fire Safety: your means of escape from a fire

Ground floor; all habitable rooms (but not a kitchen) need to open onto a hall leading to an exit, or be equipped with a window that permits escape in the event of a fire
Above ground floor; all habitable rooms need to be equipped with at least one window that permits escape in the event of a fire

Therefore; an escape window needs:

  • To be able to open to 90 degrees
  • To be no more than 1100mm off the ground
  • To have an unobstructed exit area of 0.33m2
  • To be at least 450mm wide and 450mm high
Download the Part B Guide
contact-us  request-a-quote  request-a-service-call

Services

  • Home
  • Homeowner
  • Trade
  • Architect
  • FAQs
  • Articles & Information
  • Blog
  • About Us

Contact Details

Regent Windows
Units 1/2 Malmesbury Road,
Kingsditch Trading Estate,
Cheltenham, GL51 9PL
Tel: 01242 254 222
Fax: 01242 257 100
info@regentwindows.co.uk

Get In Touch

Follow Us

  • Facebook: pages/Regent-Windows/137120082982529?sk=wall
  • Linked In: company/1602975?trk=NUS_CMPY_FOL-co
  • Twitter: #!/regentwindows
  • External Link: www.regentwindows.co.uk/news-and-pr?format=feed

About Us

​Regent Windows is a family run ​business with a manufacturing facility based in the Cotswolds. For the last 24 years Regent have been manufacturing all types of windows & doors including composite front doors, bifolding and sliding doors In both aluminium and PVCu. We also have our own sealed unit facility and own installation teams if required. All our staff members are P.A.Y.E we do not have any subcontractors.

Our customers range from small local builders to the supply and installation for some of the UK's largest national constructions companies and housing associations.

  


Learn more